6000C Series

Availability: In Stock

Designed with an inclusive cable, sensor, and adhesive cloth wrap, Nonin 6000C Series disposable cloth pulse oximetry sensors provide ultimate comfort for patients requiring extended SpO2 and pulse rate monitoring and secure placement. The sensor design features a stretch, tear-resistant cloth for easier placement and fit on the patient, especially for hard-to-fit patients such as infants and neonates, ensuring consistent readings by keeping the sensor in the proper position. Each 6000C Series disposable sensor features Nonin PureLight® technology and Nonin PureSAT® signal processing to provide consistent results from patient to patient and sensor to sensor, even under challenging patient conditions such as low perfusion.

Category:

Model 6000C

SpO2 Accuracy:
70 % to 100 % ±3 digits (Arms*)1 (Neonate)
70 % to 100 % ±2 digits (Arms*)2 (Adult)

SpO2 Low Perfusion Accuracy: 70 % to 100 % ±2 digits (Arms*)3
Pulse Rate Accuracy: 18 to 321 BPM ±3 digits (Arms*)3
Pulse Rate Low Perfusion Accuracy: 40 to 240 BPM ±2 digits (Arms*)3

* ±1 Arms encompasses 68 % of the population.
1Accuracy is based on 231 data pairs collected on 26 subjects, < 30 days of age and compared with co-oximetry data over the range of 75-100%. Accuracy specifications based on testing with Model 7500.
2Accuracy specifications based on testing with Models 2500/2500A and 9600.
3Additional accuracy and performance information can be found in the pulse oximeter operator’s manual.

Measurement Wavelengths and Output Power**:
Red: 660 nanometers @ 3 mW nominal
Infrared: 910 nanometers @ 3 mW nominal
** This information is especially useful for clinicians.

Compliance
This product complies with ISO 10993-1.
Not made from natural rubber latex.

Models 6000CP/7000P, 6000CA/7000A, 6000CI/7000I

SpO2 Accuracy:
70 % to 100 % ±2 digits (Arms*)1, 2, 3

SpO2 Low Perfusion Accuracy: 70 % to 100 % ±2 digits (Arms*)3
Pulse Rate Accuracy: 18 to 321 BPM ±3 digits (Arms*)3
Pulse Rate Low Perfusion Accuracy: 40 to 240 BPM ±2 digits (Arms*)3

* ±1 Arms encompasses 68 % of the population.
1SpO2 accuracy was conducted during induced hypoxia study on healthy subjects
over the range of 70 % to 100 %.
2Accuracy specifications based on testing with Models 2500/2500A and 9600.
3Additional accuracy and performance information can be found in the pulse oximeter operator’s manual.

Measurement Wavelengths and Output Power**:
Red: 660 nanometers @ 3 mW nominal
Infrared: 910 nanometers @ 3 mW nominal
** This information is especially useful for clinicians.

Compliance
This product complies with ISO 10993-1.
Not made from natural rubber latex.

Documentation

Videos

6000C/7000 Adult Cloth/Flexi-Form III Pulse Ox Sensors

6000C/7000 Infant/Neo Cloth/Flexi-Form Pulse Ox Sensors